Sources and applicability
- Stellantis: upstream NOx A naming
- Ford: missing NOx sensor messages
- Ford SSM 51750: specific wiring-chafe example
US manufacturer examples establish code and naming context, not UK model failure frequency. Sensor A must be identified from the installed network and exhaust diagrams.
A missing message is not an inaccurate NOx reading
U029D is lost communication with NOx sensor A. A network code reports that expected messages from a participant have not arrived; it does not assess the nitrogen oxide concentration itself. The sensor assembly can include a probe and electronic module, and an unpowered module may appear absent even when its sensing element is intact. A does not mean bank 2 or provide a universal exhaust location. The cited Stellantis note identifies A as upstream in its own installation; use the matched vehicle diagram to identify A on the vehicle being tested.
What to save when communication is intermittent
An engine-management lamp or SCR warning may appear with an unavailable sensor channel. The fault may be intermittent after wet conditions, vibration or recent electrical work, but timing alone cannot identify its cause. Save the complete multi-module report and record whether A returns online after starting. Photograph any restart countdown and state whether the vehicle starts normally. Do not repeatedly disconnect the battery to make a missing module reappear. That can erase useful context, change the network state and leave the underlying connection or supply defect unresolved.
Check dependencies before blaming the assembly
Begin with battery condition and the feeds and grounds required by sensor A. An open fuse, connector fault or loom damage can stop the module communicating. Next investigate the correct network branch and its connections using the installed topology. Only then consider a defective module or a configuration problem supported by service information. If U029E is also stored, examine shared circuitry where the diagram shows it, rather than assuming two simultaneous sensor failures. A sound-looking connector and an unloaded voltage reading do not prove the circuit remains reliable during operation.
A structured supply and communication test
Capture reporting-module identity, current versus historical status and any additional network faults. Determine whether other participants on the same branch are reachable. Inspect accessible wiring and terminals with the system safely isolated as directed, then prove power and ground under the specified load. Use protected equipment and the manufacturer network procedure to evaluate messages and connections; do not apply a universal resistance value to unidentified pins. Follow the fault tree to distinguish an absent supply from a branch interruption or an internal electronic failure, documenting the evidence for each conclusion.
Repair options, model limits and verification
Correct an established fuse-cause, terminal, feed, ground or network-harness fault. Replace the sensor/module assembly only when external checks support internal failure, using VIN-matched parts and any prescribed setup. Ford SSM 51750 lists U029D on specified 2023 6.7-litre F-Super Duty vehicles with a particular harness-chafe concern; it must not be applied as a Transit or Sprinter repair instruction. Confirm sensor A remains online and reports valid data through the appropriate operating sequence after correction. Any independent countdown needs its own repair-confirmation checks; restoring one message does not automatically establish that every SCR fault is resolved.