AdBlue fault-code library
AdBlue, SCR & NOx Fault Codes Explained
A fault code identifies a monitored condition or circuit, not automatically a failed part. Look up the code, then use the checks to understand what should happen before a repair is authorised.
Mobile call-out from £150 minimum. Final cost depends on the vehicle, location, diagnosis and work required. Contact us now for current technician availability and ETA.
Choose the guide that matches your vehicle
- P2000: NOx Adsorber Efficiency Below Threshold — Bank 1P2000 indicates low NOx adsorber efficiency on bank 1. Understand the monitor, likely causes and the checks needed before condemning a catalyst or sensor.Read the guide
- P203A: Reductant Level Sensor A CircuitP203A flags the reductant level sensor A circuit, not simply an empty tank. Learn how level data, supply checks and wiring tests separate the possible causes.Read the guide
- P203B: Reductant Level Sensor A Circuit Range/PerformanceP203B means reductant level sensor A data failed a range or performance check. Explore refill recognition, implausible readings and diagnosis before replacement.Read the guide
- P2047: Reductant Injection Valve Circuit/Open — Bank 1 Unit 1P2047 identifies an open or faulty reductant injection valve circuit on bank 1 unit 1. See the wiring, load and command checks needed before replacing parts.Read the guide
- P2048: Reductant Injection Valve Circuit Low — Bank 1 Unit 1P2048 flags a low electrical condition at the bank 1 unit 1 reductant valve circuit. Understand driver feedback, wiring checks and why low does not mean low flow.Read the guide
- P2049: Reductant Injection Valve Circuit High — Bank 1 Unit 1P2049 indicates a high electrical condition in the bank 1 unit 1 reductant valve circuit. Learn why wiring and output tests come before injector replacement.Read the guide
- P204A: Reductant Pressure Sensor CircuitP204A identifies the reductant pressure sensor circuit, not proven pump failure. See how electrical integrity and believable pressure data guide diagnosis.Read the guide
- P204B: Reductant Pressure Sensor Circuit Range/PerformanceP204B means reductant pressure feedback failed a range or performance check. Compare signal plausibility with real pressure before choosing a sensor or pump.Read the guide
- P205A: Reductant Tank Temperature Sensor A CircuitP205A flags the reductant tank temperature sensor A circuit. Learn how cold-soak comparisons, shared supplies and wiring checks prevent an unsupported tank diagnosis.Read the guide
- P205B: Reductant Tank Temperature Sensor A Circuit Range/PerformanceP205B means tank temperature sensor A failed a range or performance check. Understand cold-soak evidence, slow response and the tests needed before tank work.Read the guide
- P206A: Reductant Quality Sensor CircuitP206A identifies the reductant quality sensor circuit, not proven poor fluid. See how to separate supply, wiring and sensor faults from measured fluid condition.Read the guide
- P206B: Reductant Quality Sensor Circuit Range/PerformanceP206B flags reductant quality sensor range or performance. Learn why valid sampling, temperature context and signal checks matter before blaming the liquid.Read the guide
- P208A: Reductant Pump Control Circuit/OpenP208A identifies a reductant pump control circuit or open-circuit fault. Learn the symptoms, electrical checks and why the code alone cannot condemn the pump.Read the guide
- P208B: Reductant Pump Control Range/PerformanceP208B flags reductant pump control range or performance. Explore supply, pressure feedback and delivery checks before assuming a replacement pump is needed.Read the guide
- P20A0: Reductant Purge Control Valve Circuit/OpenP20A0 identifies the reductant purge control valve circuit or an open circuit. Understand purge operation, wiring checks and evidence needed before replacement.Read the guide
- P20BB: Reductant Heater A Control Circuit LowP20BB indicates a low electrical condition in reductant heater A control. Learn how supply, wiring and load checks differ from testing fluid temperature.Read the guide
- P20BC: Reductant Heater A Control Circuit HighP20BC identifies a high electrical condition in reductant heater A control. Check the output, wiring and heater load before blaming overheating or a failed tank.Read the guide
- P20F4: Reductant Consumption Too LowP20F4 means monitored reductant consumption is too low. Explore dosing, fluid availability and measurement checks before replacing a pump, injector or sensor.Read the guide
- P20F5: Reductant Consumption Too HighP20F5 flags reductant consumption above expectation. Learn how leakage, dosing behaviour and measurement bias are separated before any parts are replaced.Read the guide
- P20F6: Reductant Injection Valve Stuck Open — Bank 1 Unit 1P20F6 reports suspected stuck-open operation of the bank 1 unit 1 reductant valve. Learn sealing, pressure and command checks before replacing the injector.Read the guide
- P20F7: Reductant Injection Valve Stuck Open — Bank 2 Unit 1P20F7 identifies suspected stuck-open operation at the bank 2 unit 1 reductant valve. Check the correct dosing location, command and sealing before replacement.Read the guide
- P2200: NOx Sensor Circuit — Bank 1P2200 identifies a bank 1 NOx sensor circuit fault. Learn how wiring, power and sensor-module checks prevent a code-only diagnosis or unnecessary replacement.Read the guide
- P2203: NOx Sensor Circuit High — Bank 1P2203 flags a high condition in the bank 1 NOx sensor circuit. Separate electrical status from actual exhaust NOx before replacing a sensor or catalyst.Read the guide
- U010E: Lost Communication With Reductant Control ModuleU010E means communication with the reductant control module was lost. Explore power, grounds and network checks before condemning a module or tank assembly.Read the guide
- P2204: NOx Sensor Circuit Intermittent — Bank 1P2204 identifies an intermittent bank 1 NOx sensor circuit fault. Learn how to capture signal dropouts and check connections before replacing a sensor.Read the guide
- P2205: NOx Sensor Heater Control Circuit/Open — Bank 1P2205 names the bank 1 NOx sensor heater control circuit/open fault. Understand heater operation, supply checks and why a sensor is not the only suspect.Read the guide
- P2207: NOx Sensor Heater Control Circuit High — Bank 1P2207 reports a high condition in the bank 1 NOx heater control circuit. Learn what electrical checks distinguish wiring problems from heater or driver faults.Read the guide
- P2208: NOx Sensor Heater Sense Circuit — Bank 1P2208 identifies the bank 1 NOx sensor heater sense circuit. Learn how feedback differs from heater control and what to check before replacing the assembly.Read the guide
- P2209: NOx Sensor Heater Sense Circuit Range/Performance — Bank 1P2209 flags bank 1 NOx heater sense range/performance. Understand feedback plausibility, warm-up checks and why this differs from a circuit high or low fault.Read the guide
- P2211: NOx Sensor Heater Sense Circuit High — Bank 1P2211 reports a high condition in the bank 1 NOx heater sense circuit. Learn how feedback and supply checks differ from diagnosing a heater control fault.Read the guide
- P20A2: Reductant Purge Control Valve Circuit LowP20A2 identifies a low electrical condition in the reductant purge valve circuit. Learn how purge control, wiring and supply checks differ from pressure diagnosis.Read the guide
- P20EA: Reductant Control Module Power Relay De-Energized Performance — Too EarlyP20EA means the reductant module power relay de-energises too early. Learn how shutdown timing, voltage loss and relay checks differ from a failed AdBlue pump.Read the guide
- P20EB: Reductant Control Module Power Relay De-Energized Performance — Too LateP20EB flags late de-energisation of the reductant module power relay. Understand shutdown timing, possible retained power and tests before replacing a module.Read the guide
- P20ED: SCR NOx Pre-Catalyst — Over Temperature, Bank 1P20ED reports bank 1 SCR NOx pre-catalyst over temperature. Learn how temperature validation and upstream checks separate genuine overheating from bad data.Read the guide
- P20EC: SCR Catalyst Over Temperature — Bank 1P20EC reports SCR catalyst over-temperature on bank 1. Learn how temperature plausibility, dosing and exhaust checks separate false readings from excess heat.Read the guide
- P2BAE: NOx Control Monitoring System FaultP2BAE concerns NOx exceedance and its control monitoring system. Understand companion codes, sensor validity and repair verification before requesting a reset.Read the guide
- P204C: AdBlue Pressure Sensor Circuit LowP204C means the reductant pressure sensor circuit is low, not proven low fluid pressure. Learn supply, signal and pump checks before replacing an assembly.Read the guide
- P204D: AdBlue Pressure Sensor Circuit HighP204D identifies a high reductant pressure sensor circuit input. Distinguish an electrical fault from genuinely excessive pressure before approving pump work.Read the guide
- P205C: AdBlue Tank Temperature Circuit LowP205C reports a low reductant tank temperature sensor circuit input. Learn why electrical low is not a thermometer reading and how to check heater decisions.Read the guide
- P208E: AdBlue Injection Valve Stuck ClosedP208E reports a reductant injection valve stuck closed on bank 1 unit 1. Compare commands, electrical faults and delivery response before cleaning or replacing it.Read the guide
- P20A1: AdBlue Purge Valve PerformanceP20A1 concerns reductant purge control valve performance. Learn how shutdown pressure response, circuit integrity and delivery-path checks guide a lawful repair.Read the guide
- P22A7: NOx Sensor 2 Heater PerformanceP22A7 concerns NOx sensor 2 heater performance or readiness on bank 1. Validate supply, feedback and vehicle-specific wording before replacing the sensor.Read the guide
- P221C: AdBlue Heater B Current Too LowP221C means reductant heater B current is too low. Identify the heated circuit and compare current with its command before approving a tank or line replacement.Read the guide
- U029D: Lost Communication With NOx Sensor AU029D means communication with NOx sensor A was lost. Learn how sensor identification, supply integrity and network checks prevent an unnecessary replacement.Read the guide
- U029E: Lost Communication With NOx Sensor BU029E reports lost communication with NOx sensor B. Distinguish a missing downstream participant from bad conversion data and verify wiring before fitting parts.Read the guide
Related diagnostic guides
24 hours a day, 7 days a week
Not sure which fault you have? Send the exact warning
Include the registration, postcode and whether the vehicle still starts. Mobile call-out from £150 minimum. Final cost depends on the vehicle, location, diagnosis and work required. Contact us now for current technician availability and ETA.